17 Field Sources#
Defines current and magnetic-field sources and external electric circuits. It also defines permanent magnets for magnetic-field analysis and electric-field sources for electric-field analysis.
Input settings#
17_Field_Source(17) JSON key: field-source object
SOURCE(17) Text format: field-source object
COIL_LINE_APPROX_LIMIT(17) Distance threshold for applying the COIL line-current approximation
Input format#
Text-format section
- Type:
Fixed parameter set 1
- Number of rows:
1
- Number of parameters:
1
Text format#
* SOURCE *
SOURCE
JSON format#
JSON format from 2024.11#
"17_Field_Source" :
[
{
"COIL" :
{
"SERIES_ID" : I,
"TIME_ID" : I,
"IN_ROTOR" : I,
"POTENTIAL" : I,
"TO_MESHED_COIL" : I,
"data" :
[
{
"TYPE" : I,
"CURRENT" : I,
...
}
]
}
},
{
"CIRCUIT" :
{
"REGION_FACTOR" : I,
"REGION_PARALLEL" : I,
"SERIES_ID": [I],
...
}
},
{
"COIL_LINE_APPROX_LIMIT" : E
}
]
Detailed description#
17_Field_Source (JSON), SOURCE (text format only)#
- 17_Field_Source(17)#
- SOURCE(17)#
Identifier defining a source
COIL_LINE_APPROX_LIMIT#
- COIL_LINE_APPROX_LIMIT(17)#
- Data type:
Real number (E, >= 0)
- Description:
Specifies the distance threshold beyond which the line-current approximation is applied from a COIL.
The default is 1000. Increasing the value applies the line-current approximation only at more distant positions. Specifying 0 leaves the default unchanged.