7. Initial Conditions#

Specifies initial conditions for analysis.

Input settings#

7_Initial_Conditions JSON key: initial conditions object

INITIAL_STEP(7) Sets the initial-value step

DATA_TYPE(7) Specifies initial conditions by data type

INITIAL_PHASE(7) Sets the initial phase when frequency-domain analysis (AC != 0) results are used as initial values

MULTI(7) Setting for time-domain analysis (TRANSIENT = 1) using steady-current eddy-current analysis (STEADY_CURRENT = 1) results as initial values

OUTPUT_STEP_NO(7) Changes output step numbering during post-processing of restart analysis

CYCLE_AC(7) Setting for restart calculation that uses frequency-domain analysis results as initial values in Darwin model time-domain analysis

Input format#

Text-format section
Type:

Fixed parameter set

Number of rows:

1

Number of parameters:

5

Text format#
* INITIAL_STEP * DATA_TYPE * INITIAL_PHASE * MULTI * OUTPUT_STEP_NO * CYCLE_AC *
        I               I             E            I           I       E

JSON format#

JSON format from 2024.11#
"7_Initial_Conditions" :
{
    "INITIAL_STEP" : I,
    "DATA_TYPE" : I,
    "INITIAL_PHASE" : E,
    "MULTI" : I,
    "OUTPUT_STEP_NO" : I,
    "CYCLE_AC" : E
},

Important

Release 2024.11

In JSON format, default values are used when these parameters are not defined. See the detailed descriptions for default values.

Detailed description#

7_Initial_Conditions#

7_Initial_Conditions#
JSON key:

Initial conditions object

INITIAL_STEP#

INITIAL_STEP(7)#
Text-format section
Fixed parameter set 1#
[row, col] = [1, 1]
Initial conditions setting#

Setting value

Description

-1

Sets all initial conditions to zero. Default

≥0

Uses the solution at INITIAL_STEP(9) in old_solutions as the initial condition.

Note

For static analysis (STATIC(2) = 1), the solutions file is written from step 1. For time-domain analysis (TRANSIENT(2) = 1), the step 0 solution is the initial condition itself. For frequency-domain analysis (AC(2) = 1), set this to 0.

DATA_TYPE#

DATA_TYPE(7)#
Text-format section
Fixed parameter set 1#
[row, col] = [1, 2]
Initial conditions setting by data type#

Setting value

Description

0

Uses static analysis STATIC(2) or time-domain analysis TRANSIENT(2) results as initial values. Default

1

Uses frequency-domain analysis AC(2) results as initial values.

2

Uses steady-current eddy-current analysis STEADY_CURRENT(2) results as initial values.

3

Uses old_solutions as initial values.

Active when INITIAL_STEP != -1.

INITIAL_PHASE#

INITIAL_PHASE(7)#
Text-format section
Fixed parameter set 1#
[row, col] = [1, 3]
Data type:

Real number (E)

Unit:

degree

Description:

Sets the phase (degree) when frequency-domain analysis (AC(2) = 1) results are used as initial values. When steady-current eddy-current analysis STEADY_CURRENT(2) results are used for transient analysis after changing the mesh model’s angular width, enter the mesh model’s minimum angle from the steady-current analysis.

MULTI#

MULTI(7)#
Text-format section
Fixed parameter set 1#
[row, col] = [1, 4]
Data type:

Integer (I)

Description:

When transient analysis uses steady-current eddy-current analysis (STEADY_CURRENT(2) = 1) results as initial values, specifies the multiplier used after changing the mesh model’s angular width.

Default value:

0

OUTPUT_STEP_NO#

OUTPUT_STEP_NO(7)#
Text-format section
Fixed parameter set 1#
[row, col] = [1, 5]
Data type:

Integer (I)

Description:

Use to change the step number normally treated as step 0 at restart. For example, with 10, the restart step is step 10 and post-processing output starts at step 11.

Default value:

0

CYCLE_AC#

CYCLE_AC(7)#
Text-format section
Fixed parameter set 1#
[row, col] = [1, 8]
Data type:

Real number (E)

Unit:

sec

Description:

For Darwin model time-domain analysis that uses frequency-domain analysis results with AC(2) = 3 or 5 as initial values, specify one period of the original frequency-domain analysis in seconds. This determines the value at the phase one time step before the initial value. Darwin model time-domain analysis discretizes a second-order time-derivative term, so it requires the previous-step value in addition to the initial value.

Default value:

0

Warning

When restarting from an initial run, the mesh, potentials, and circuit power-supply configuration must not change. Adding an electric scalar potential or changing a constant-current source to a constant-voltage source is permitted. Restarting from coupled equation-of-motion analysis requires renaming the corresponding files.