17.10 Equipotential-Surface Electric-Field Source#
An equipotential-surface electric-field source used for static electric-field (STATIC(2) = 2) and steady-current-field (STATIC(2) = 3) analysis.
Input settings#
EPOTSUF(17.10) JSON key: equipotential-surface electric-field source object
SERIES_ID(17.10)Series ID
SURFACE_MAT_ID(17.10)Surface-element property ID
POT_OR_CHARGE(17.10)Specifies potential or charge
TIME_ID(17.10)Time-data ID
UNIT_TYPE(17.10)Specifies the input unit
Input format#
Text-format section
- Type:
Fixed parameter set 1
- Number of rows:
1
- Number of parameters:
6
* EPOTSUF * SERIES_NO * SURFACE_MAT_ID * POT_OR_CHARGE * TIME_ID * UNIT_TYPE *
EPOTSUF I I I I I
JSON format#
"17_Field_Source" :
[
{
"EPOTSUF" :
{
"SERIES_ID" : I,
"SMAT_ID" : I,
"POT_OR_CHARGE" : I,
"TIME_ID" : I,
"UNIT_TYPE" : I
}
}
]
Detailed description#
An equipotential-surface electric-field source is defined as a surface element.
EPOTSUF#
- EPOTSUF(17.10)#
Text-format section
[row, col] = [1, 1]
Type=S
Specifies the equipotential-surface electric-field source EPOTSUF.
SERIES_ID#
- SERIES_ID(17.10)#
Text-format section
[row, col] = [1, 2]
- Data type:
Integer (I)
- Description:
Source-term identifier.
SURFACE_MAT_ID#
- SURFACE_MAT_ID(17.10)#
Text-format section
[row, col] = [1, 3]
Type=I
Property ID of the surface elements forming the equipotential surface.
POT_OR_CHARGE#
- POT_OR_CHARGE(17.10)#
Text-format section
[row, col] = [1, 4]
Type=I(0,1)
<When STATIC = 2>
= 0: Specifies the total surface charge (C) within the equipotential surface on a conductor surface. Potential is unknown. When total charge (C) is given to a dielectric surface, surface potential is unknown.
= 1: Specifies potential (V). Total charge is unknown.
<When STATIC = 3>
= 0: Specifies the total current (A) passing through the equipotential surface. Potential is unknown.
= 1: Specifies potential (V). Total current is unknown.
TIME_ID#
- TIME_ID(17.10)#
Text-format section
[row, col] = [1, 5]
Type=I
Data ID specifying the time variation TIME_ID(18).
Specifies the time variation of charge (current) or potential according to POT_OR_CHARGE.
UNIT_TYPE#
- UNIT_TYPE(17.10)#
Text-format section
[row, col] = [1, 6]
Type=I(0,1)
<When STATIC = 2>
Specifies the input unit for the total surface charge when POT_OR_CHARGE = 0
= 0: (C)
= 1: (C/m²)